Note
Action
xx1000001111
Remove the
plastic screws
in the upper end of
the balancing device.
4
Insert two
screws, M12x50
in the holes to
neutralize the spring force. Screw in the screws
until they have proper contact with the cylinder
inside.
5
The length of the cylinder is now locked and
the balancing device is unloaded. It should now
be possible to easily rotate the balancing
device.
xx1000001112
Attach a
lifting accessories
to the balancing
device.
Use the
hole
in the lifting ear.
6
Continues on next page
280
Product manual - IRB 760
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the balancing device
Continued