Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
2
xx1000001092
Remove the
motor cover
to get access to the
connectors on top of the motor.
3
xx1000001094
Remove the
cable gland cover
at the cable exit
of the motor.
Note
Make sure the gasket is undamaged! Replace
if damaged.
4
Disconnect all connectors beneath the motor
cover.
5
Connect to connector R2.MP1
•
+ : pin 2
•
-: pin 5
In order to release the brake, connect the 24
VDC power supply.
6
xx1000001090
Remove the
attachment screws
of the motor.
Use the bits extension.
7
Continues on next page
Product manual - IRB 760
293
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.6.1 Replacing motor, axis 1
Continued