Information
Action
A
xx0600002694
Refit the cable gland with its attachment screw.
13
•
A: Screw holding the cable
gland
Make sure the gasket is not damaged!
Replace if damaged.
xx1000001106
Refit the cover, motor axis 6 with its
attachment
screws
and
washers
.
Note
Make sure the cover is tightly sealed!
14
Pendulum Calibration is described in
Operating manual - Calibration Pendu-
lum
, enclosed with the calibration
tools.
Recalibrate the robot!
15
Axis Calibration is described in
rating with Axis Calibration method on
page 360
General calibration information is in-
cluded in section
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section
16
Product manual - IRB 760
315
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.6.3 Replacing motor, axis 6
Continued
Summary of Contents for IRB 760 Series