Installation, signal lamp
Use this procedure to install the signal lamp to the robot.
Note
Action
See figure
.
Fit the
signal lamp bracket
to the tilthouse, with
two
attachment screws
.
1
See figure
.
Fit the signal lamp to the bracket, with two
attach-
ment screws
.
2
See
Electrical installation, signal
If not already connected, connect the signal lamp
to the axis 6 motor.
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
3
See figure
.
Arrange the signal cable in a loop at the signal
cable bracket with two
cable straps
.
4
Electrical installation, signal lamp
Use this procedure to connect the signal lamp to the axis 6 motor. The instruction
requires that the signal lamp is already mounted to the tilthouse.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
1
See figure
.
Remove the
motor cover
by unscrewing the four
attachment screws.
2
Disconnect the motor connectors.
3
Continues on next page
86
Product manual - IRB 760
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
2 Installation and commissioning
2.3.9 Installation of signal lamp, upper arm (option)
Continued
Summary of Contents for IRB 760 Series
Page 1: ...ROBOTICS Product manual IRB 760 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 400: ......
Page 401: ......