Note
Action
See figure
.
A
xx0600002694
Remove the
cable gland cover
at the cable exit
by removing the attachment screw.
Replace the screw with a longer one, when refit-
ting in following steps (enclosed in the signal
lamp kit).
4
A Screw that holds the cable
gland
Enclosed with signal lamp kit.
See how the
adapter
is going to be fitted to the
motor and then fit the
gasket
to the side of the
adapter that will be facing downwards. The gas-
ket will protect the mating surfaces of the adapter
and the cable gland cover.
5
See figure
.
Place
gasket and motor adapter
above the cable
gland cover and refit the complete package to
the motor. Secure with
attachment screw M6x40
,
enclosed with the signal lamp kit.
6
In addtion to the enclosed gasket that
is fitted to the adapter, there is also
a gasket located on the motor. Make
sure it does not get damaged. Re-
place if damaged!
Push the signal cable through the hole in the
adapter and connect it to the connector inside
the motor.
7
Loosen the motor cables at the glands and adjust
their lengths with + 20 mm into the motor.
8
Connect motor cables inside the motor.
9
Secure motor cables at cable gland again.
10
Fit the motor cover with the attachment screws.
11
Make sure the cabling is placed correctly when
refitting the cover and does not get jammed.
Product manual - IRB 760
87
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
2 Installation and commissioning
2.3.9 Installation of signal lamp, upper arm (option)
Continued
Summary of Contents for IRB 760 Series
Page 1: ...ROBOTICS Product manual IRB 760 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 400: ......
Page 401: ......