2 Installation and commissioning
2.6.5. Installation of position switches (option)
109
3HAC022033-001 Revision: E
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
Axis 1
The illustration below shows the position switch for axis 1. There is no extra cabling installed
on the robot, as for axes 2 and 3. Instead the switch is connected directly to the connector in
the base, R1.SW1.
xx0100000158
A
Position switch, axis 1
B
Cam
C
Set screw, cam (cam stop)
D
Protection sheet
E
Rail
F
Rail attachment
Continued
Continues on next page