Note
Action
xx1500002717
Remove the cable gland cover.
Tip
Make a note in which direction the cable
exit hole is facing, if the motor shall be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Disconnecting the axis-1, axis-2, axis-3 and axis-4 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001135
Unscrew the attachment screws with
washers and remove the motor cover.
2
Continues on next page
204
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued