Note
Action
xx1300000728
Connect all connectors to the SMB board:
R1.SMB1-3, R1.SMB4-6 and R2.SMB
4
xx1300000730
Carefully push the SMB unit into position and
refit the bracket.
5
X9
X8
X10
xx1700000978
If disconnected, reconnect the connectors X8,
X9 and X10 to the brake release board.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms
are snapped down properly.
6
xx1300000834
Take a hold of the SMB cover and pull the battery
cable out through the recess for the battery.
7
Continues on next page
234
Product manual - IRB 8700
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.4.3 Replacing the SMB
Continued