Note
Action
Remove the brake release unit from the bracket, if it
should be replaced.
4
Refitting the brake release unit
Use these procedures to refit the brake release unit.
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
1
Maximum tightening torque: 5
Nm.
Fasten the brake release unit to the bracket.
2
xx1300000744
Refit the bracket with the brake release unit fitted.
Make sure the unit is placed as straight as possible
on the bracket. The push buttons can otherwise get
jammed when the SMB cover is refitted.
3
X9
X8
X10
xx1700000978
Reconnect the connectors X8, X9 and X10 to the
brake release unit.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms are
snapped down properly.
4