Note
Action
Attachment screws: M12x50 12.9
Gleitmo (30 pcs)
xx1500003104
Fit 28 of the 30 attachment screws.
6
xx1500003103
Remove the guide pins and replace them with the
remaining screws.
7
Tightening torque: 120 Nm
Secure the wrist.
8
Remove the lifting accessories.
9
Connecting the axis-5 motor cables
Note
Action
xx1500002717
Push the motor cables in through the cable
gland opening.
1
Continues on next page