Note
Action
Flange sealant: Loctite 574
xx1600000049
Apply flange sealant (Loctite 574) on the
contact surface between parallel arm and
counterweight.
5
xx1500001982
Use caution and lift the counterweight up
onto the parallel arm.
6
Attachment screws: M16x70 Gleitmo (10
pcs)
Fit attachment screws with washers and
secure the counterweight to the parallel
arm.
7
Tightening torque: 300 Nm
xx1500001981
Remove lifting accessories; lifting chains
and the lifting eyes.
8