Note
Action
xx1500002308
Restore the pressure of the balancing
device by unscrewing the two M16x80
screws alternately little by little.
2
Remove the screws.
3
Attachment screws: M16x35 (2 pcs)
xx1500001971
Refit the M16x35 screws in the holes on
top of the balancing device.
4
Concluding procedure
Note
Action
DANGER
Make sure all safety requirements are met
when performing the first test run.
1
Product manual - IRB 8700
447
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.6.4 Unloading and restoring the balancing device