Note
Action
For robots with protection class
IP30
xx2100000933
Remove the screws on the cover of the outer arm
and remove the cover.
Note
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the cover with bellow and housing.
Note
The bellow does not need to be removed separ-
ately.
Tip
Check the gasket and replace it if needed.
3
For robots with protection class
IP54 (option 3350-540)
For robots with protection type
Clean Room (option 3351-1)
xx2100002427
Disconnecting the air hoses, C1 cabling and C2 cabling (if equipped)
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
Continues on next page
272
Product manual - IRB 920
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the axis-1 timing belt
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......