Note
Action
Screws: Hex socket head cap
screw M3x8 12.9 Lafre 2C2B/FC6.9
(2 pcs)
Secure the cable ferrule to the bracket.
Tip
Align all the cable ferrules so that the cable is in
a natural bending position to avoid twisting.
Tightening torque: 1.2 Nm ±10%
xx2100000951
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
Screws: Hex socket head cap
screw M3x8 12.9 Lafre 2C2B/FC6.9
(4 pcs)
Refit the base bracket to the base and secure with
the screws.
4
Tightening torque: 1.2 Nm ±10%
xx2100000948
Refitting the SMB cover
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Continues on next page
Product manual - IRB 920
301
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the axis-1 timing belt
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......