Note
Action
Tightening torque: 2.5 Nm ±10%
xx2100002408
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Pull the upper end of the bellow to the outer arm.
Tip
For robots with protection class IP54 (option 3350-
540)
Hold the bellow for a little while until it's attached
to the housing.
4
For robots with protection class IP54 (option 3350-
540)
5
Install the bellow gaskets to the bellow.
Tip
The angle between the gap on the bellow gasket
and gap on the inner bellow gasket should be 90
degrees.
For robots with protection class IP54 (option 3350-
540)
6
For robots with protection type Clean Room (op-
tion 3351-1)
Secure them with the clamp.
Tip
The opening part of the clamp should be in the
opposite position to the gap on the bellow gasket.
Refitting the lower cover and the flange with bearing
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Continues on next page
Product manual - IRB 920
525
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the ball screw
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......