Note
Action
For rear outlet cable version:
xx2100000954
Pull the internal harness out of the outer arm from
the centre of the axis-2 gearbox.
Tip
Wrap the connectors with the masking tape.
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
3
For undeneath outlet cable version:
xx2100001203
Removing the main harness from the axis -1 gearbox position
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
Continues on next page
Product manual - IRB 920
735
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.7.1 Replacing the axis-1 motor sub-assembly
Continued