Note
Action
For undeneath outlet cable version:
For robot with undeneath outlet cable version,
remove the screws on the main harness assembly.
5
For robots with protection class
IP30 (option 3350-300)
xx2100001204
Remove the main harness assembly.
Note
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Check the gasket for the main harness assembly.
Tip
Replace the gasket if needed.
6
For robots with protection class
IP54 (option 3350-540)
Note
Remove the bottom plate from the main harness
if needed.
For robots with protection type
Clean Room (option 3351-1)
xx2100002437
xx2200000281
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the one way valve by unscrewing it.
7
Removing the pulley protection cover
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
738
Product manual - IRB 920
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.7.1 Replacing the axis-1 motor sub-assembly
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......