Note
Action
xx2100001034
Snap loose and remove the female head of the
connectors from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
6
Disconnecting the connectors for axis-2 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx2100000934
Disconnect the connectors.
•
R2.MP2
•
R2.FB2
3
Continues on next page
Product manual - IRB 920
851
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gear unit sub-assembly
Continued