Check that the synchronization marks on axes 3
and 4 are aligned with each other.
Are they aligned within the tolerances?
•
If yes, the calibration is verified OK.
•
If no, redo the fine calibration procedure.
4
See
.
Update the revolution counters of axes 3 and 4.
5
After calibration
Note
Action
Write down the new system parameters on a new
label and stick on top of the calibration label on
the robot.
1
Note
The calibration status of axis 3 may be changed to
Not updated
after a system
reinstallation or warm restart. In this case, update the revolution counters for
axis 3 and axis 4 (axis 4 is coupled with axis 3). See
974
Product manual - IRB 920
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
6 Calibration
6.5.3 Calibrating axis 3 and axis 4
Continued