Note
Action
WARNING
Used oil is hazardous material and must
be disposed of in a safe way. See
for more informa-
tion.
7
Note
Draining is time-consuming.
Elapsed time varies depending on the
temperature of the oil.
Drain the gearbox oil.
8
Remove the quick coupling connector and
clean the pipe after the oil is drained.
Note
There will be some oil left in the gearbox
after draining.
9
Tightening torque: 10 Nm
Refit oil plugs.
10
Removing the process hub screws
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
For robots with protection class
IP30
Remove the screws locking the process hub.
2
xx2300000487
Push the process hub to the outer arm.
3
Continues on next page
Product manual - IRB 930
175
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Summary of Contents for IRB 930
Page 1: ...ROBOTICS Product manual IRB 930 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 600: ...This page is intentionally left blank ...
Page 604: ......
Page 605: ......