Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 32
2
xx1300000670
If needed, disconnect the brake release unit (connect-
ors X8, X9 and X10).
3
xx1300000730
Remove the screws with washers that hold bracket
with the SMB unit.
4
xx1300000728
Carefully pull the SMB unit out a little and disconnect
the connectors from the SMB board:
•
R1.SMB1-3, R1.SMB4-6 and R2.SMB
•
Battery cable connector R2.G.
Disconnect the battery cable by pressing down
the upper lip of the R2.G connector to release
the lock while pulling the connector upwards.
5
xx1700000993
Continues on next page
Product manual - IRB 8700
237
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.3 Replacing the SMB
Continued
Summary of Contents for IRC5 Compact