Note
Action
xx1300000488
Reconnect the connectors to the axis-6
motor.
Note
Place the resolver cable underneath the
motor cable.
5
xx1500003095
Make sure the gasket on the motor cover
is undamaged.
Note
Replace if damaged.
6
CAUTION
Make sure not to damage the cables inside
the motor when refitting the motor cover.
7
Attachment screws: M5x20 (5 pcs)
xx1200001080
Refit the motor cover.