Note
Article number
Equipment, etc.
Content is defined in section
.
-
Standard toolkit
Required consumables
Note
Article number
Consumable
Loctite 243
3HAB7116-1
Locking liquid
Mercasol 3110 Waxcoat. Recom-
mended drying time is 24h.
3HAC034903-001
Rust preventive
Removing the mechanical stop pin
Use these procedures to remove the mechanical stop pin.
Robot position when replacing the mechanical stop pin
Note
Action
xx1500002093
Jog axis-1 to the position where it is pos-
sible to replace the mechanical stop pin.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
2
Removing the mechanical stop pin
Note
Action
CAUTION
The mechanical stop pin weighs 13 kg.
1
Continues on next page