Performing a leak-down test
Note
Action
See
Performing a leak-down test on
Perform a leak-down test.
1
Preparations before refitting the axis-1 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure and air pressure are turned
off.
1
Remove old paint residues and other contamina-
tion from the contact surfaces on both motor and
gearbox.
2
Wipe clean the contact surfaces from any remain-
ing contamination.
3
Also wipe clean the o-ring groove.
O-ring, 3HAB3772-107
xx1200001019
Inspect the o-ring.
Note
Replace if damaged.
4
xx1200001020
Make sure the o-ring is seated in the groove.
Tip
Lubricate the o-ring with some grease for a better
fitting in the groove.
5
Continues on next page
666
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.8.2 Replacing the axis-1 gearbox
Continued