Note
Action
xx1200001067
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Removing the axis-2 motor
Note
Action
DANGER
When releasing the holding brakes of the
motor, the lower arm and/or the parallel
arm will move and may fall down!
Before continuing, make sure the lower
arm and/or parallel arm are secured with
lock screws.
1
To release the brake, connect the 24 VDC
power supply to the motor in question.
2
Connect to connector R2.MP2 (axis-2 mo-
tor) or R2.MP3 (axis 3-motor):
•
pin 2 = 24V
•
pin 5 = 0V
Bits extender: 3HAC12342-1
xx1500002323
Remove the attachment screws that secure
the motor.
Tip
Use a bits extender in order to reach the
screws.
3
Guide pin, M10x150: 3HAC15521-2
Fit guide pins in opposite holes.
4
Always use guide pins in pairs.
Continues on next page