Connecting the axis-3 motor cables
Note
Action
xx1300000738
Push the motor cables through the cable
gland opening.
1
xx1200001067
Refit the cable gland cover.
Note
Replace the gasket if damaged.
2
xx1200001066
Connect the motor cables.
Connect in accordance with the markings
on the connectors.
3
Continues on next page
Product manual - IRB 8700
753
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.8.4 Replacing the axis-3 gearbox
Continued