32568, Axis computer firmware file error
Description
The file
arg
, required to upgrade an axis computer's firmware,
is not usable because it failed the integrity check.
Consequences
The required upgrade of the axis computer firmware is not
performed.
Probable causes
The firmware file is corrupt.
Recommended actions
Reinstall the system.
32569, Corrupt axis computer hardware
Description
In drive module
arg
, the axis computer flash memory has a
corrupt content.
Recommended actions
Retry again by restarting the controller using the main power
switch. If the problem remains then replace the axis computer.
32570, Firmware re-flash started
Description
A required update of the
arg
firmware has started. Replacing
old firmware version: [
arg
].
Recommended actions
Wait for the re-flash to complete.
32571, Firmware re-flash completed
Description
The update of
arg
firmware has completed successfully. New
version: [
arg
]. Internal code:[
arg
]
32572, Firmware re-flash failed
Description
The upgrade of
arg
firmware failed.
Current version:
arg
. Internal error code:
arg
.
Recommended actions
Check other hardware eventlog messages for detailed
explanation of the error condition. Reinstall the system.
32573, Unable to download firmware file
Description
The firmware file
arg
is not found. Internal error code:
arg
.
Recommended actions
Reinstall the system.
32574, Corrupt axis computer hardware
Description
The
arg
flash memory has a corrupt content. Internal error
code:
arg
.
Recommended actions
Check other hardware event log messages for detailed
explanation of the error condition. Restart the controller. If
failure occurs again, replace the axis computer.
32575, Found no axis computer board
Description
System failed to detect any connected axis computer.
Recommended actions
Check system for axis computer board. Check Ethernet cables
between the main computer and the axis computer. Restart the
controller.
32576, Axis firmware: No communication
Description
The system failed to communicate with axis board
arg
when
trying to check the firmware version.
Consequences
The system is unable to check and if necessary upgrade the
firmware in the affected axis computer.
Recommended actions
Check system for axis computer board. Check Ethernet cables
between the main computer and the axis computer. Restart the
controller.
32577, Axis computer hardware data error
Description
In drive module
arg
, the axis computer has corrupt information
stored on the unit.
Consequences
The system goes to system failure state.
Probable causes
The integrity check of the axis computer information stored on
the unit has failed.
Continues on next page
164
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.5 3 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......