Recommended actions
Check cables and connections. Check contactor.
37213, Fault on contactor KM102
Description
A fault is observed on motor contactor KM102.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Check contactor.
37214, Run chain 1 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on run chain 1 feedback signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
37215, Run chain 2 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on run chain 2 feedback signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
37216, Brake chain 1 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on brake chain 1 feedback signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
37217, Brake chain 2 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on brake chain 2 feedback signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
37218, Cabin Interlock chain 1 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on cabin interlock chain 1 feedback
signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
37219, Cabin Interlock chain 2 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on cabin interlock chain 2 feedback
signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
37220, HV Interlock chain 1 feedback conflict
Description
Safety interface board (SIB) and manipulator interface board
(MIB)
arg
reports divergence on high voltage (HV) interlock
chain 1 feedback signals.
Consequences
The system goes to status SYS HALT.
Recommended actions
Check cables and connections. Replace SIB if faulty. Replace
MIB if faulty.
Continues on next page
184
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.5 3 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......