40668, Shapedata Not In Use
Description
Task:
arg
.
The '
arg
' argument of the instruction
arg
must refer to a defined
shapedata.
Program ref:
arg
.
Recommended actions
A shapedata is used to store a volume definition. It must have
been defined by WZBoxDef, WZSphDef or WZCylDef before it
can be used by WZLimSup or WZDOSet.
40669, World Zone Too Small
Description
Task:
arg
.
At least one side or radius is less than the minimal allowed in
instruction
arg
.
Program ref:
arg
.
Recommended actions
Check previous volume definition instruction.
40670, Invalid World Zone
Description
Task:
arg
.
The index of the world zone argument
arg
in
arg
is not a valid
index defined by WZLimSup or WZDOSet.
Program ref:
arg
.
Recommended actions
Check the RAPID program.
40671, Illegal Use Of World Zone
Description
Task:
arg
.
The argument '
arg
' for
arg
must be a temporary world zone.
Program ref:
arg
.
Recommended actions
Check the argument.
40672, World Zone Already In Use
Description
Task:
arg
.
It is not possible to add the world zone
arg
. Another world zone
with the same name is already defined in the system.
Program ref:
arg
.
Recommended actions
Check the name of the world zone.
40673, I/O Access Error
Description
Task:
arg
.
The signal given in parameter
arg
is write protected for RAPID
access.
Program ref:
arg
.
Recommended actions
Select other user signal or change the access mode for the
signal.
40674, I/O Access Error
Description
Task:
arg
.
The I/O signal
arg
is not write protected for user access from
FlexPendant or RAPID.
Program ref:
arg
.
Recommended actions
Change the access mode to type ReadOnly for the signal in the
I/O configuration.
40675, Execution Error
Description
Not allowed changing the run mode from forward to backward
or vice versa when running an invisible trap routine.
Recommended actions
If possible, select the original run mode and press start to
continue.
40676, Parameter Error
Description
Task:
arg
.
The DeltaJointVal for robot axis
arg
is <= 0.
Program ref:
arg
.
Recommended actions
Check the value for DeltaJointVal. The DeltaJointVal for all axes
to supervise must be > 0 mm or degrees.
40677, Parameter Error
Description
Task:
arg
.
The DeltaJointVal for external axis
arg
is <= 0.
Continues on next page
Operating manual - Troubleshooting IRC5
249
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.6 4 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......