41848, Too low visualization time
Description
Task:
arg
.
The specified visualization time is too low.
Program ref:
arg
.
Consequences
The program execution is stopped immediately.
Recommended actions
Check the RAPID documentation regarding the minimum
visualization time. Increase the visualization time used in the
RAPID program.
41849, Bad combination of values used in
arguments
Description
Task:
arg
.
The specified visualization time
arg
is equal or higher than the
timeout
arg
for the instruction.
Program ref:
arg
.
Consequences
The program execution is stopped immediately.
Recommended actions
Change the visualization time used in the RAPID program, or
change the maximum period of waiting time permitted.
41850, User interface already active
Description
Task:
arg
.
A message is already active on the FlexPendant. A message
launched by instruction
arg
must be aborted before launching
a new message.
Program ref:
arg
.
Consequences
The message will not be presented on the FlexPendant. This
error can be handled in an error handler.
Probable causes
A
arg
message is already active on the FlexPendant.
Recommended actions
Recovery:
arg
. The current active
arg
message can be
deactivated with instruction
arg
.
41851, Wrong value type used
Description
Task:
arg
.
Wrong value type used in optional argument
arg
. The only valid
types are bool, num or dnum, or any alias type of those three
base types.
Program ref:
arg
.
Consequences
The program execution is stopped immediately.
Probable causes
Wrong value type used.
Recommended actions
Change type used in optional argument
arg
.
41852, Wrong signal value for signal
arg
Description
It is not possible to set the I/O signal
arg
to value
arg
.
Consequences
The program execution is stopped immediately.
Probable causes
The I/O signal
arg
is configured wrong, or the value that should
be set is wrong. The signal value that is used has been read
from a persistent variable specified in one of the setup
instructions used for Trigg defining conditions and actions for
setting a digital, a group of digital, or an analog output signal
at a fixed position. The error is detected when the actual signal
setting should be done.
Recommended actions
Check the I/O configuration for I/O signal. Check the value of
the persistent variable that is used in
arg
for the setup
instruction(s) for Trigg.
41860, Evaluation error in Cyclic bool
Description
Failure while evaluating the Cyclic bool
arg
.
Consequences
The evaluation of
arg
has been stopped immediately.
Probable causes
The module containing the declaration of
arg
has been
unloaded. An I/O signal needed to evaluate the logical
expression connected to
arg
has been lost (see earlier error
logs). The I/O signal that is updated with the cyclic bool value
has been lost.
Continues on next page
318
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.6 4 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......