71350, Invalid network
Description
The I/O configuration is invalid.
The device predefined type
arg
has an invalid/unknown type
of network
arg
.
Installed valid Industrial Networks are:
arg arg arg
.
Consequences
This device predefined type has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the network for the device predefined type.
71351, Invalid connection 1 type
Description
The I/O configuration is invalid.
The unit type
arg
has an invalid/unknown type for connection
1
arg
.
The type for connection 1 must be one of the following: POLLED
STROBE COS CYCLIC COS_ACKSUP CYCLIC_ACKSUP This
unit type has been rejected.
Recommended actions
Correct the connection 1 type of the unit type.
71352, Invalid connection 2 type
Description
The I/O configuration is invalid.
The unit type
arg
has an invalid/unknown type for connection
2
arg
.
The type for connection 2 must either be omitted or one of the
following: POLLED STROBE COS CYCLIC COS_ACKSUP
CYCLIC_ACKSUP This unit type has been rejected.
Recommended actions
Correct the connection 2 type of the unit type.
71354, I/O device without reference to network
Description
The I/O configuration is invalid.
No reference to a network is defined for the I/O device
arg
.
This I/O device has been rejected.
Recommended actions
Define a network reference for the I/O device.
71355, Invalid Device Trust Level
Description
The I/O configuration is invalid.
I/O device
arg
has an invalid/unknown Device Trust Level:
arg
.
Installed valid Device Trust Levels are:
arg
.
Consequences
This I/O device has been rejected, and no functions depending
on it will work.
Recommended actions
Correct the Device Trust Level for the I/O device.
71356, Bus type mismatch
Description
The I/O configuration is invalid.
Device
arg
refers to a network and a unit type with different bus
types.
This I/O device has been rejected.
Recommended actions
Check that the I/O device is connected to the correct network
and that the bus type of that network is correct. Check that the
I/O device refers to the correct unit type and that the bus type
of that unit type is correct.
71357, Duplicated I/O devices on network Local
Description
The I/O configuration for I/O device
arg
is invalid.
There is already another user-defined I/O device connected to
the network Local.
Only one user-defined I/O device may be connected to the
network Local.
This I/O device has been rejected.
Recommended actions
Correct the I/O configuration.
71361, Cross connection with non-digital
resultant I/O signal
Description
The I/O configuration of cross connection
arg
is invalid.
The parameter Resultant refer to an I/O signal
arg
, that is not
digital.
Only digital I/O signals can be cross connected.
Consequences
The cross connection has been rejected, and no functions
depending on it will work.
Continues on next page
380
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.8 7 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......