90467, SC
arg
STS speed exceeded
Description
Safe reduced Tool Speed (STS) in Safety Controller (SC) on
mechanical unit
arg
too high. Cause
arg
.
Probable causes
Tool0 speed. Elbow speed. Tool speed. Additional axis speed.
Recommended actions
Reduce tool speed.
90468, SC
arg
STZ violation
Description
Safe Tool Zone (STZ)
arg
is violated on mechanical unit
arg
.
Tool
arg
was active.
Cause
arg
.
Probable causes
Exceeded speed. Wrong tool position. Wrong tool orientation.
Wrong elbow position. Wrong tool point 1 position. Wrong tool
point 2 position. Wrong tool point 3 position. Wrong tool point
4 position. Wrong tool point 5 position. Wrong tool point 6
position. Wrong tool point 7 position. Wrong tool point 8
position.
Recommended actions
Reduce speed. Move robot tool to safe position. Adjust tool
orientation.
90469, SC
arg
SAR violation
Description
Safe Axis Range (SAR)
arg
is violated on mechanical unit
arg
axis
arg
.
Recommended actions
Move mechanical unit to safe position.
90470, SC
arg
Synchronization Pre-warning
Description
Synchronization required for mechanical units supervised by
Safety Controller (SC)
arg
in less than
arg
hour(s).
Recommended actions
Perform synchronization before the time limit expires.
90471, SC
arg
Synchronization Timeout
Description
Synchronization time limit expired for Safety Controller (SC)
arg
.
Recommended actions
Perform synchronization.
90472, SC
arg
New safety configuration
Description
Safety Controller (SC)
arg
has received a new safety
configuration. A new PIN-code is needed to activate.
Recommended actions
Log in as a user with safety configuration grants. Enter new
PIN-Code for the Safety Controller in the Control Panel.
90473, SC
arg
Dual Computer mismatch
Description
Safety Controller (SC)
arg
have had conflicting values for a
Safety Output for too long.
Consequences
The Safety Controller has entered a Safe State and issue an
error after 10 minutes of internal mismatch, if recommended
actions are not performed.
Probable causes
The mechanical unit have been parked at a position on, or close
to, a supervised or monitored function limit for too long time.
Internal computation error in Safety Controller.
Recommended actions
Move all mechanical units' axes and tools well inside or outside
monitored and supervised function limits.
90474, SC
arg
I/O Supply Failure
Description
I/O supply voltage level for Safety Controller (SC)
arg
is out of
range.
Probable causes
Either the voltage is out of limits or the voltage is missing.
Recommended actions
Connect 24V supply with correct voltage level to I/O supply
terminals. Restart robot controller.
90475, SC
arg
Synchronization rejected
Description
Safety Controller (SC)
arg
is not correctly configured for
synchronization.
Continues on next page
Operating manual - Troubleshooting IRC5
419
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.9 9 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......