Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90612, Device attribute insize is invalid
Description
Device
arg
attribute insize is empty or not a number.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90613, Device attribute outsize is invalid
Description
Device
arg
attribute outsize is empty or not a number.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90614, Could not attach device to net
Description
Attaching device
arg
to net
arg
failed because the device is
already attached to net
arg
.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90615, Could not attach device to net
Description
Attaching device
arg
to net
arg
failed.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90616, Could not find device
Description
Could not find device
arg
.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90617, Device attribute is missing
Description
Device
arg
attribute
arg
is missing on line
arg
.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Recommended actions
Update the safety configuration.
90618, Device attribute is invalid
Description
Device
arg
attribute
arg
is invalid on line
arg
.
Consequences
The system will stop all robot movements.
Probable causes
The safety configuration has not been created using
RobotStudio.
Continues on next page
430
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.9 9 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......