It is only possible to run spot instructions with software
equalizing activated in semi coordinated mode.
Consequences
It will not be possible to run any spot instructions with software
equalizing activated until the synchronized mode is disabled.
Probable causes
Synchronized mode is selected in the spot instruction.
Recommended actions
Turn off software equalizing to be able to run in synchronized
mode or change the spot instructions to semi coordinated
movements instead.
110665,
arg
Description
Task:
arg
arg
arg
Recommended actions
arg
110666, Servo gun already closed
Description
Task:
arg
Can not close a closed servo gun, the servo gun
arg
is not
open!
Probable causes
The gun is already closed.
Recommended actions
Open the gun before trying to close it.
110667, Gun force calibration error
Description
Task:
arg
Force calibration failed for servo gun
arg
.
Check the force calibration values and try again. Do not restart
system until a valid force calibration is made.
Consequences
The force calibration data will not be saved to the motion
parameters.
Recommended actions
Check the values and try to do a force calibration again.
110668, Plate thickness error ignored
Description
Task:
arg
arg
The current plate thickness error was ignored.
Current gun:
arg
argarg
Probable causes
The operator probably ignored the thickness error.
Recommended actions
Check that it was OK to ignore the thickness error.
110669, Gun index number out of range
Description
Task:
arg
The gun number
arg
is not a valid gun number, the gun index
is out of range.
Allowed values are:
arg
to max
arg
.
Consequences
It will not be possible run this instruction until this value is
changed.
Probable causes
A gun index number that was out of range was programmed in
the instruction.
Current configured size of current gundata is
arg
.
Recommended actions
1. Change the gun index number in the instruction.
2. Increase the number of equipments in the configuration, and
the spot application data types if needed.
110670, User module changed
Description
Task:
arg
The routine
arg
has a newer syntax, the user module has
changed since previous RobotWare releases.
Current module:
arg
Current version:
arg
Consequences
This instruction might not work correctly, some data(s) may not
be updated correctly.
There is a risk that improvements and/or corrections added
since previous RobotWare releases are unavailable.
Continues on next page
484
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.10 11 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......