3.10 Reflashing firmware failure
Description
When reflashing firmware, the automatic process can fail.
Consequences
The automatic reflashing process is interrupted and the system stops.
Possible causes
This fault usually occurs due to a lack of compatibility between hardware and
software.
Consequences
The following actions are recommended (listed in order of probability):
Information
Action
The logs may also be accessed from
RobotStudio.
Check the event log for a message specifying
which unit failed.
1
Was the relevant unit recently replaced?
2
If YES; make sure the versions of the old and
new unit is identical.
If NO; check the software versions.
Was the RobotWare recently replaced?
3
If YES; make sure the versions of the old and
new unit is identical.
If NO; proceed below!
Check with your local ABB representative for
a firmware version compatible with your hard-
ware/software combination.
4
54
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
3 Troubleshooting by fault symptoms