File:
arg
. Line:
arg
.
Consequences
The configuration in file will not be installed correctly.
Probable causes
The parameter is not valid.
Recommended actions
Re-edit the configuration file and reload the cfg file.
120016, Invalid
arg
Description
Parameter '
arg
' has an invalid value: '
arg
'
Valid values:
arg
arg
Consequences
The configuration in file will not be installed correctly.
Probable causes
The value might be mistyped.
Recommended actions
Re-edit the configuration file and reload the cfg file.
120017, Invalid Rapid Identifier
Description
The value '
arg
' of parameter '
arg
' for configuration instance '
arg
'
is invalid.
Consequences
The configuration in file will not be installed.
Probable causes
The value might be mistyped.
Recommended actions
Correct the value of the parameter so that it complies with the
following rules:
Rules of RAPID identifiers: The length must not exceed 16
characters. The first character must be a letter (a-z or A-Z).
Subsequent characters must be letters (a-z or A-Z), digits (0-9)
or underscores (_).
540
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
5.11 12 xxxx
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Operating manual Troubleshooting IRC5 ...
Page 10: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 586: ...This page is intentionally left blank ...
Page 588: ......
Page 589: ......