time, by pressing and holding the compass button. A compass will be shown that
indicates the direction.
The device is referenced.
xx1400002072
The device needs to be referenced.
xx1400002073
Note
Sensor errors lead to a growing deviation of the orientation in horizontal direction.
To keep the quality of the orientation at a high level the T10 has to be referenced
about every 10 minutes.
Programming the function keys
The function keys are four hardware buttons on the T10 that can be used for
dedicated specific functions set by the user, see
As default, the key F1 is configured as
AutoAck
. The other buttons are not
configured with any function. Any button (including F1) can be configured with any
of the following settings:
Description
Action
No action will be performed (default).
None
Acknowledges an auto change.
AutoAck
Moves the program pointer of all tasks to their respective main routine.
PPToMain
Starts execution of the currently selected tasks in the task panel.
StartRapid
Stops all tasks.
StopRapid