Note/Illustration
Action
xx1800001979
Check that no pipe has been damaged, and that
the grease is distributed to each block and on the
pinion.
4
Checking grease level and inspect the pipes with lubrication feedback system
When lubrication feedback system is used, there will be an abnormal alarm on the
FlexPendant if anything is not ok in the lubrication system.
The procedure below details how to troubleshoot the lubrication system when the
lubrication feedback system has abnormal alarm happened.
Note/Illustration
Action
Locate the cartridge.
1
xx1800001978
Check the level of lubricant. If the lubricant is used
up, change with a new one.
2
For cartridge replacement, see the
.
Check if the lubrication pump is working normally.
If not, check:
•
The battery is low or not. If yes, replace the
battery. (Although the replacement battery
should be delivered with the replacement
cartridge, note that it is possible to use a
set of 3 pcs standard AA batteries).
•
The EPS system is working normally or not.
If no, replace the cartridge.
3
Continues on next page
210
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.5.2 Automatic lubrication system
Continued
Summary of Contents for IRT 710
Page 1: ...ROBOTICS Product manual IRT 710 ...
Page 14: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 84: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 383: ......