Required equipment
Note
There are different variants of SMB units and batteries. The variant with the
3-pole battery contact has longer lifetime for the battery.
It is important that the SMB unit uses the correct battery. Make sure to order the
correct spare parts. Do not replace the battery contact!
Note
Art. no.
Equipment, etc.
Content is defined in section
-
Standard toolkit
Replacing the SMB battery pack
Use this procedure to replace the SMB battery pack.
Note
Action
DANGER
Turn off all electric power, hydraulic and pneumat-
ic pressure supplies to the robot and for the track
motion.
1
Position first the carriage in the calibration posi-
tion (align the synchronization gauges).
2
WARNING
Turn off all electric power, hydraul-
ic and pneumatic pressure supplies
to the robot and for the product.
Switch off the power on the SMB box.
3
Open the SMB box and locate the battery.
4
Cut the plastic straps.
5
Unplug the 2 wires cable from the board and re-
move the battery pack.
6
Place the new battery pack, plug the connector
on the board, and secure the pack with straps.
7
Close the SMB box, switch on the power.
8
Update the revolution counters of the axis.
9
Product manual - IRT 710
215
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.6.1 Replacing the SMB battery pack
Continued
Summary of Contents for IRT 710
Page 1: ...ROBOTICS Product manual IRT 710 ...
Page 14: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 84: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 383: ......