Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the product, before entering the safeguarded
space.
3
Removing the distributor
Note
Action
Disconnect the tubes.
1
xx2200000824
Remove the screws locking the distributor.
2
Refitting the distributor
Use this procedure to refit the distributor.
Refitting the distributor
Note
Action
xx2200000824
Refit the distributor and secure with the
screws.
1
Screws: ISO 4762 M6x20 Class 8.8 (2 pcs)
Washers: BN 792 M6 Washer (2 pcs)
Tightening torque: 10 Nm
Connect the tubes.
2
Continues on next page
Product manual - IRT 710
255
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.2.4 Replacing the lubrication parts
Continued