Note/Illustration
Action
xx1800001979
Check that no pipe has been damaged, and that
the grease is distributed to each block and on the
pinion.
4
After installing the lubrication feedback system,
check the lubrication status regularly (at least for
three months) to avoid incorrect feedback.
5
Memolub manual
The procedure below is based on the Memolub HPS user manual. It details how
to replace the grease cartridge.
Opening and closing the Memolub
Note
Action
xx1800001980
Opening the Memolub.
First place the Memolub on a flat and clean sur-
face. Push firmly with one hand on top of the
Memolub. With the other hand, hold the black
base and turn counterclockwise. Pull the transpar-
ent bell to open.
1
xx1800001981
Closing the Memolub.
Use the same technique: hold the cranked black
base, put the transparent bell and turn it clock-
wise. When the closed position is reached you
should hear a "click".
2
Installing a new grease cartridge
Respect the following instructions to replace the grease cartridge:
Note
Action
Open the Memolub
®
as described before.
1
Continues on next page
Product manual - IRT 710
211
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.5.2 Automatic lubrication system
Continued
Summary of Contents for IRT 710
Page 1: ...ROBOTICS Product manual IRT 710 ...
Page 14: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 84: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 383: ......