6.3 Updating revolution counters
6.3.1 Updating revolution counters for axis calibration
Introduction
This section describes how to do a rough calibration of each track axis by updating
the revolution counter for each axis, using the FlexPendant.
Step 1 - Manually running the manipulator to the synchronization position
Use this procedure to manually run the manipulator to the synchronization position.
Note
Action
Select axis-by-axis motion mode.
1
Use the nearest synchronization mark.
Jog the carriage to align the synchroniza-
tion marks.
2
xx2300001326
Step 2 - Updating the revolution counter
with the FlexPendant on page 342
When all axes are positioned, update the
revolution counter.
3
Step 2 - Updating the revolution counter with the FlexPendant
Use this procedure to update the revolution counter with the FlexPendant.
Action
On the start screen, tap
Calibrate
.
1
Select
Calibration
from the menu.
2
The
Mechanical Units
page displays a list of available mechanical units.
Note
This step is required only if you are not already in the
Mechanical Unit
page when
you open
Calibrate
.
Note
The
Mechanical Unit
page is displayed only if there are more than one mechanical
unit available. Otherwise, the calibration summary page for the available mechanical
unit is displayed.
Select the mechanical unit for which revolution counter need to be updated.
3
Continues on next page
342
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.3.1 Updating revolution counters for axis calibration
Summary of Contents for IRT 710
Page 1: ...ROBOTICS Product manual IRT 710 ...
Page 14: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 84: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 383: ......