6.3.2 Updating revolution counters for pin calibration
Procedure
This procedure must be applied if revolution counter value is loss for the Track.
Note/Illustration
Action
xx2300001300
Align the sharp edge of the moving part of the
calibration marker with the line of the fixed part
calibration marker.
1
Tap
ABB
on the top left of the FlexPendant.
2
Tap
Calibration
.
3
Select the desired mechanical unit.
4
Tap
Update revolution counters
.
5
Select the desired axis.
6
Tap
Update
.
7
344
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.3.2 Updating revolution counters for pin calibration