background image

2

LLT10 0

 

|

  L A SER L E V EL T R A N SM I T T ER  |  C I/L LT 10 0 - EN R E V. A

1  Health & Safety

 WARNING   

Bodily injury

 

Read the LLT100 Operating Instruction 

OI/LLT100-EN

  

care fully before working with the product.  
For personal and system safety, and for optimum 
performance, make sure that you thoroughly un derstand 
the contents before installing, using or maintaining this 
instrument.

NOTICE  

•  All servicing of the equipment is to be per formed at 

factory by qualified service person nel only.

•  No user / operator adjustments inside the LLT100 level 

transmitter are recommended by the manufacturer.

Product labels

Symbols that appear on this product are shown below:: 

  Protective earth (ground) terminal.

  Direct current supply only.

2  Electrical connection

HART terminal – 2 wires

Internal protective earth  

(ground)

Cover lock screw M4

Positive (+)
Negative (–)
*Optional external  

  meter (+)

External ground 

termination point

HART terminal with heater option –  

2 + 2 wires

Internal protective earth  

(ground)
External DC supply: 

+24 V DC, 3 W

Cover lock screw M4

0 V (return)

Positive (+)
Negative (–)
*Optional external  

  meter (+)

External ground 

termination point

 

Attention – location of ground

 

The Ground symbols is used to identify protective 
earth conductor terminals.

 

Attention – direct current

 
Use wires and cable glands rated 90 °C (194 °F) minimum.

Reviews: