40
L ST 3 0 0 |
CO M PAC T U LT R A S O N I C L E V EL T R A N SM I T T ER | L S T 3 0 0 – EN R E V. E
2
Press
or
to scroll through the different process
values .
Area
Description
Ins
The instant distance measured during the last
measurement . This corresponds to the distance of
the echo shown in the waveform .
Tem
The measured process temperature .
Sig
The size of the echo as shown in the waveform (in mV)
Selecting True Echo Index (TEI)
The True Echo Index is used together with the True Echo
Detection function . Information on applying this function is
shown in Section of this document .
1
Press
to switch until the current process values box in
the top left is highlighted .
2
Press
to enter the “True Echo Index” menu .
3
Press
to select the position to be changed .
4
Press
or
to scroll through the different process
values .
5
Press
to confirm your selection .
Changing waveform zoom
1
Press
to switch until the waveform zoom level box in the
bottom right is highlighted .
2
Press
to zoom in and view more details .
3
Press
to zoom out to have a wider view of the
measurement range .
4
After zooming in, press
or
to scroll back to the
original or other zoom view levels .
Scrolling the x-axis
1
When zoomed in, press
to switch until the waveform
x-axis offset box in the bottom left is highlighted .
2
Press
to scroll to the right to be further from the sensor
and closer to the maximum measurement range .
3
Press
to scroll to the left to be closer to the sensor and
further from the maximum measurement range .
Summary of Contents for LST300 Series
Page 26: ...26 LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E...
Page 27: ...LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E 27...
Page 28: ...28 LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E...
Page 59: ...LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E 59 Note...