Electrical installation: input / output 75
E1 / E2: Ethernet port configuration
The rotary switches are read once at startup. The switches select the mode of
operation for the E1 and E2 Ethernet fieldbus connectors on the top panel of the
drive. See page
Value
Mode
00
EtherCAT slave mode
01-EF
Ethernet POWERLINK CN mode: selected value is node ID
F0-FF
Reserved
E3: Ethernet host
The Ethernet host port is used to connect a PC for configuring the MicroFlex e190.
See section
on page
for details about configuring the PC’s Ethernet
adapter for communication with the MicroFlex e190.
The host port also can be used for Modbus TCP, Ethernet/IP and PROFINET fieldbus
connections.