Technical data 157
Dimensions and weights
For basic weights and dimensions, see
on page
Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment.
Operation
installed for stationary
use
Storage
in the protective
package
Transportation
in the protective
package
Installation site altitude
0 to 2000 m (6560 ft) above
sea level. [See also section
-
-
Air temperature
1.6 A model:
0 to +50 °C (32 to 122 °F)
3 A, 6 A, 9 A models:
0 to +55 °C (32 to 131 °F).
No frost allowed.
See section
on
page
.
-40 to +70 °C
(-40 to +158 °F)
-40 to +70 °C
(-40 to +158 °F)
Relative humidity
0 to 95%
Max. 95%
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60%
in the presence of corrosive gases.
Contamination levels
No conductive dust allowed.
The drive must be installed
in clean air according to
enclosure classification.
Cooling air must be clean,
free from corrosive materials
and electrically conductive
dust.
Sinusoidal vibration:
EN 60068-2-6: 2008
Tested according to,
mechanical conditions:
2…9 Hz: 3.0 mm (0.12”)
9…200 Hz: 1g
–
–
Shock:
EN 60068-2-27: 2009
IEC 60068-2-27:2008
–
Max. 10g, 11 ms
Max. 10g, 11 ms
Free fall
Not allowed
76 cm (30”)
76 cm (30”)
Summary of Contents for MicroFlex e190
Page 1: ...ABB motion control User s manual MicroFlex e190 servo drive ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 26: ...26 Introduction to the manual ...
Page 90: ...90 Electrical installation input output ...
Page 146: ...146 Maintenance ...
Page 178: ...178 Resistor braking ...
Page 186: ...186 Accessories ...
Page 208: ...208 Appendix Safe Torque Off STO ...