Reference 65
500Bh 0
REC AX0_TorqueFilter_1_REC
REC
-
Number of torque filter 1 parameters
1
TorqueFilterType_I16
INT16
RW No
-
Maps to TORQUEFILTERTYPE(0, 1)
2
TorqueFilterFreq_U16
UINT16 RW No
Hz
Maps to TORQUEFILTERFREQ(0, 1)
3
TorqueFilterBand_U16
UINT16 RW No
Hz
Maps to TORQUEFILTERBAND(0, 1)
4
TorqueFilterDepth_U16
UINT16 RW No
0.1 %
units
Maps to TORQUEFILTERDEPTH(0,
1)
500Ch 0
VAR AX0_ErrorInputMode_I16
INT16
RW No
-
Maps to ERRORINPUTMODE
500Dh 0
VAR AX0_FolErrorMode_I16
INT16
RW No
-
Maps to FOLERRORMODE
500Eh 0
VAR AX0_LimitMode_I16
INT16
RW No
-
Maps to LIMITMODE
500Fh 0
VAR AX0_SoftLimitMode_I16
INT16
RW No
-
Maps to SOFTLIMITMODE
5011h 0
VAR AX0_VelFatalMode_I16
INT16
RW No
-
Maps to VELFATALMODE
5013h 0
ARR AX0_HallTable_State0_AU16
ARRAY RO
No
-
Number of Hall states
1
HallTable_U16
UINT16 RW No
Sextant Maps to HALLTABLE(0,1)
2
HallTable_U16
RW No
Sextant Maps to HALLTABLE(0,2)
3
HallTable_U16
RW No
Sextant Maps to HALLTABLE(0,3)
...
6
HallTable_U16
RW No
Sextant Maps to HALLTABLE(0,6)
5014h 0
ARR
AX0_HallForwardAngle_Sextant0
_AI16
ARRAY RO
No
-
Number of Hall states
1
HallForwardAngle_I16
INT16
RW No
1° units Maps to HALLFORWARDANGLE(0,1)
2
HallForwardAngle_I16
RW No
1° units Maps to HALLFORWARDANGLE(0,2)
3
HallForwardAngle_I16
RW No
1° units Maps to HALLFORWARDANGLE(0,3)
...
6
HallForwardAngle_I16
RW No
1° units Maps to HALLFORWARDANGLE(0,6)
5015h 0
ARR
AX0_HallReverseAngle_Sextant0
_AI16
ARRAY RO
No
-
Number of Hall states
1
HallReverseAngle_I16
INT16
RW No
1° units Maps to HALLREVERSEANGLE(0,1)
2
HallReverseAngle_I16
RW No
1° units Maps to HALLREVERSEANGLE(0,2)
3
HallReverseAngle_I16
RW No
1° units Maps to HALLREVERSEANGLE(0,3)
...
6
HallReverseAngle_I16
RW No
1° units Maps to HALLREVERSEANGLE(0,6)
5016h 0
REC AX0_PhaseSearch_REC
REC
RO
No
-
-
1
PhaseSearchMode_U16
UINT16 RW No
-
Maps to PHASESEARCHMODE
2
PhaseSearchBackoff_I16
INT16
RW No
Maps to PHASESEARCHBACKOFF
3
PhaseSearchBandwidth_I16
INT16
RW No
Rad/s
Maps to
PHASESEARCHBANDWIDTH
4
PhaseSearchSpeed_I16
INT16
RW No
-
Maps to PHASESEARCHSPEED
6
PhaseSearchTravel_I16
INT16
RW No
-
Maps to PHASESEARCHTRAVEL
7
PhaseSearchCurrent_I16
INT16
RW No
0.1 %
units
Maps to PHASESEARCHCURRENT
5022h 0
VAR AX0_TorqueLimitNeg_I16
INT16
RW No
0.1 %
units
Maps to TORQUELIMITNEG
5023h 0
VAR AX0_TorqueLimitPos_I16
INT16
RW No
0.1 %
units
Maps to TORQUELIMITPOS
5027h 0
ARR AX0_CurrentMeasX_AI32
ARRAY RO
No
-
Number of current measurement
channels
1
Drive current
INT32
RO
Poss. mA
Maps to CURRENTMEAS(0, 0)
502Bh 0
VAR AX0_CompareOutput_I16
INT16
RW No
-
Maps to COMPAREOUTPUT
Index Sub-
ind.
Obj. Name
Type
Attr. PDO
Mapp
ing
Units
Description
Summary of Contents for MotiFlex e180
Page 1: ...ABB motion control Application guide MotiFlex e180 EtherCAT ...
Page 4: ......
Page 14: ...14 Safety ...
Page 20: ...20 Physical connection ...
Page 70: ...70 Reference ...