A.6 Read-only, single precision float
Description
Slot
Index
Object type
Data type
Bytes
Store
Access
Notes
Sensor 1 – Concentration
40
0
Simple
Float
4
D
R
See engineering ranges
Sensor 1 – Temperature
40
1
Simple
Float
4
D
R
Sensor 2 – Concentration
40
2
Simple
Float
4
D
R
Sensor 2 – Temperature
40
3
Simple
Float
4
D
R
Sensor 3 – Concentration
40
4
Simple
Float
4
D
R
Sensor 3 – Temperature
40
5
Simple
Float
4
D
R
Sensor 4 – Concentration
40
6
Simple
Float
4
D
R
Sensor 4 – Temperature
40
7
Simple
Float
4
D
R
Table A.10: Measurement values
Description
Slot
Index
Object type
Data type
Bytes
Store
Access
Notes
Sensor 1 – Concentration
40
8
Simple
Float
4
D
R
Single-stream – sensor 1
Sensor 1 – Temperature
40
9
Simple
Float
4
D
R
Sensor 1 – Raw signal
40
10
Simple
Float
4
D
R
Sensor 1 – Flow rate
40
11
Simple
Float
4
D
R
Sensor 1 – Active calibration slope
40
12
Simple
Float
4
D
R
Sensor 1 – Active calibration offset
40
13
Simple
Float
4
D
R
Sensor 1 – Last calibration slope
40
14
Simple
Float
4
D
R
Sensor 1 – Last calibration offset
40
15
Simple
Float
4
D
R
Sensor 2 – Concentration
40
16
Simple
Float
4
D
R
Single-stream – sensor 2
Sensor 2 – Temperature
40
17
Simple
Float
4
D
R
Sensor 2 – Raw signal
40
18
Simple
Float
4
D
R
Sensor 2 – Flow rate
40
19
Simple
Float
4
D
R
Sensor 2 – Active calibration slope
40
20
Simple
Float
4
D
R
Sensor 2 – Active calibration offset
40
21
Simple
Float
4
D
R
Sensor 2 – Last calibration slope
40
22
Simple
Float
4
D
R
Sensor 2 – Last calibration offset
40
23
Simple
Float
4
D
R
Sensor 3 – Concentration
40
24
Simple
Float
4
D
R
Single-stream – sensor 3
Sensor 3 – Temperature
40
25
Simple
Float
4
D
R
Sensor 3 – Raw signal
40
26
Simple
Float
4
D
R
Sensor 3 – Flow rate
40
27
Simple
Float
4
D
R
Sensor 3 – Active calibration slope
40
28
Simple
Float
4
D
R
Sensor 3 – Active calibration offset
40
29
Simple
Float
4
D
R
Sensor 3 – Last calibration slope
40
30
Simple
Float
4
D
R
Sensor 3 – Last calibration offset
40
31
Simple
Float
4
D
R
Sensor 4 – Concentration
40
32
Simple
Float
4
D
R
Single-stream – sensor 4
Sensor 4 – Temperature
40
33
Simple
Float
4
D
R
Sensor 4 – Raw signal
40
34
Simple
Float
4
D
R
Sensor 4 – Flow rate
40
35
Simple
Float
4
D
R
Sensor 4 – Active calibration slope
40
36
Simple
Float
4
D
R
Sensor 4 – Active calibration offset
40
37
Simple
Float
4
D
R
Sensor 4 – Last calibration slope
40
38
Simple
Float
4
D
R
Sensor 4 – Last calibration offset
40
39
Simple
Float
4
D
R
Table A.11: Sensor signals view