3BSE083159
34
Section 3 Interface Modules
Referring Documents
Cable Factory Reset on NE870
It is possible to set the unit to factory default settings by using two straight standard
Ethernet RJ-45 cables.
1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
2. Connect an Ethernet cable between Ethernet port 1/1 and Ethernet port 1/2 (that
is, connect Ethernet ports 1 and 2 on in the left most slot by an Ethernet cable).The
ports need to be connected directly by an Ethernet cable, that is, not through a hub
or switch. Use a straight cable – not a cross-over cable – when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red.
The ON LED flashing indicates that the unit is now ready to be reset to factory
default. You now have the choice to go ahead with the factory reset, or to skip
factory reset and boot as normal.
Proceed with Factory Reset
Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet
cables. The ON LED will stop flashing. This initiates the factory reset process, and
the unit will restart with factory default settings.
Type
Description
Document Number
User Manual
ABB NEOS User Manual
3BSE080654 en
Network Configuration
Guide
System 800xA Network
Configuration Guide
3BSE034463 en
Summary of Contents for NE870
Page 1: ...800xA Networks NE870 User Manual ...
Page 2: ......